xPC Target    

IP-HiADC Analog Input (A/D)

Scaling Input to Output

Hardware Input
Block Output Data Type
Scaling
volts
double
1

Driver Block Parameters

Carrier ID -- Enter the Carrier ID of the IP carrier board into which the IP module is plugged.

In order to use an IP module, it must be physically plugged into an IP carrier board and the model must contain a block representing this carrier board. Each carrier block has a `Carrier ID' parameter, which must be set to a number not shared by any other carrier board block in the model.

Carrier slot -- Select the slot on the carrier board into which the IP-HiADC module is plugged. Note that different carrier boards can have different slot capacities.

Channel vector -- Enter a vector of numbers between 1 and 16. The channel numbers can occur in any order. For example, to use the first and third analog output (A/D) channels, enter

[1, 3]

Number the channels beginning with 1 even if the board manufacturer starts numbering the channels with 0.

Range -- Select either -5V to 5V or -10V to 10V. This applies to all channels.

Sample time -- Enter the base sample time or a multiple of the base sample time.


  IP-HiADC IP-Synchro