xPC Target | ![]() ![]() |
The Quartz-MM5 has one AM9513A chip with 5 counters.
The Quartz-MM5 FM & ARM driver programs the AM9513A for FM (Frequency Modulation) signal generation (a square wave with fixed duty cycle and variable frequency). Additionally the driver allows to arm and disarm the counter by the second block input. For the corresponding counter channel, the PWM signal is output at the pin named OUT.
Scaling Input to Output
Hardware Output |
Block Input Data Type |
Scaling |
TTL |
Variable frequency: double Arm: double |
<0.5 disarmed >0.5 armed |
Driver Block Parameters
Counter -- From the list, choose 1
, 2
, 3
, 4
, 5
, 6
, 7
, 8
, 9
, or 10
to select which counter is used with this driver block. In each case, one block is needed for each counter.
Frequency base -- From the list, choose F1=1MHz
, F2=100kHz
, F3=10kHz
, F4=1kHz
, or F5=100Hz
to set the base frequency. The XTAL frequency is assumed to be 1MHz, therefore the jumper on the CIO-CTR05 has to be in position 1MHz not 5MHz.
Output duty cycle -- Enter a value between 0
and 1
to set the duty cycle of the square wave. The Duty Cycle is held fixed during execution of the target application.
Level sequence of square wave -- From the list, choose either high-low
or low-high
.
high-low
, the square wave period starts with the TTL high part followed by the TTL low part.
low-high
, the square wave period starts with the TTL low part followed by the TTL high part.
In either case, the Output duty cycle defined in the setting above define the duration of the TTL high part.
Level when disarmed -- From the list, choose either high
or low
. The counter is automatically disarmed when the target application is not running. If the application is running, the second input port controls whether the counter is armed or disarmed. This parameter sets the TTL level when the counter is disarmed.
Sample time -- Enter the base sample time or a multiple of the base sample time. The sample time indicates the update rate of registration on the input (Duty Cycle)
Base address -- Enter the base address of the board. This entry must corresponds to the DIP-switch settings on the board. For example, if the base address is 300 (hexadecimal), enter
![]() | Quartz-MM5 Counter FM | Quartz-MM5 PWM Capture | ![]() |