xPC Target | ![]() ![]() |
The CIO-PDISO16 has two independent connectors. Each connector has 8 relay driven digital input lines.
Use a separate diver block for each connector.
Scaling Input to Output
Hardware Output |
Block Input Data Type |
Scaling |
relay |
double |
< 0.5 = Relay open > 0.5 = Relay closed |
Driver Block Parameters
Number of Channels -- Enter a number between 1 and 8 to select the number of digital output lines used with this connector. This driver does not allow the selection of individual digital output lines.
Section(Connector) -- From the list, choose either 1 (nearest to backplate)
or 2 (farthest from backplate
to select the connector used.
Sample time -- Enter the base sample time or a multiple of the base sample time.
Base address -- Enter the base address of the board. It is important that this entry corresponds to the DIP-switch settings on the board. For example, if the base address is 300 (hexadecimal), enter
The Wait-State jumper has to be in the off position.
The switch and jumper settings, that are not mentioned here, have no influence on the running of xPC Target.
![]() | CIO-PDISO16 Digital Input | CIO-QUAD02 | ![]() |