xPC Target    

CIO-PDISO16 Digital Output

The CIO-PDISO16 has two independent connectors. Each connector has 8 relay driven digital input lines.

Use a separate diver block for each connector.

Scaling Input to Output

Hardware Output
Block Input Data Type
Scaling
relay
double
< 0.5 = Relay open
> 0.5 = Relay closed

Driver Block Parameters

Number of Channels -- Enter a number between 1 and 8 to select the number of digital output lines used with this connector. This driver does not allow the selection of individual digital output lines.

Section(Connector) -- From the list, choose either 1 (nearest to backplate) or 2 (farthest from backplate to select the connector used.

Sample time -- Enter the base sample time or a multiple of the base sample time.

Base address -- Enter the base address of the board. It is important that this entry corresponds to the DIP-switch settings on the board. For example, if the base address is 300 (hexadecimal), enter

The Wait-State jumper has to be in the off position.

The switch and jumper settings, that are not mentioned here, have no influence on the running of xPC Target.