xPC Target | ![]() ![]() |
CIO-DAS16/JR Analog Input (A/D)
Scaling Input to Output
Hardware Input |
Block Output Data Type |
Scaling |
volts |
double |
1 |
Driver Block Parameters
Number of Channels -- If single-ended
is chosen from the MUX list, enter a number between 1 and 16 to select the number of A/D channels used. If differential is chosen from the MUX list, enter a number between 1 and 8 to select the number of A/D channels used. This driver does not allow the selection of individual channels or to mix single-ended and differential inputs.
Number the channels beginning with 1 even if the board manufacturer starts numbering channels with 0.
Range -- From the list, choose either +-10V
(-10 volts to +10 volts), +-5V
, +-2.5V
, +-1.25V
, +-0.625V
, 0-10V
, 0-5V
, 0-2.5V
, or 0-1.25V
.This driver does not allow the selection of a different range for each channel.
MUX -- From the list, choose either single-ended(16 channels)
or differential (8 channels)
. This choice must correspond to the MUX-switch setting on the board.
Sample time -- Enter the base sample time or a multiple of the base sample time.
Base address -- Enter the base address of the board. It is important that this entry corresponds to the DIP-switch settings on the board. For example, if the base address is 300 (hexadecimal), enter
![]() | CIO-DAS16/JR (/12) | CIO-DAS16/JR (/12) Analog Input (A/D) with EXP Signal Conditioning Board | ![]() |