CAGE User's Guide    

Setting Up Tables

To set up tables in CAGE, you first open the Calibration Manager dialog box. Do this by selecting Tools -> Calibration Manager or by clicking  in the toolbar.

You can either set up your tables manually or from a calibration file. You can also copy table data from other sources.

Setting Up Tables Manually

  1. Select the normalizer or table to set up from the list on the left.
  2. Enter the number of rows and columns in the edit boxes in the Manual Setup pane and select initial values for each cell in the table.

  1. Check the display of your table, then click Close.

Setting Up Tables Using an Existing Calibration File

  1. Open the file by clicking .
  1. This opens the Import Calibration dialog box.

  1. Select the type of file you want to open (M or Mat file) or select Automatic. Click OK to open the file browser.
  2. Browse to the calibration file, select it and click Open.

  1. Highlight both the table in the Contents of Calibration File pane and the table in the Calibratable Blocks pane that you want to associate with it.
  2. Associate these two files by clicking .
  1. To associate all the items listed in the Calibratable Blocks pane with items having the same names listed in the Contents of Calibration File pane, click .

  1. Check the display of your table, then click Close.

Contact The MathWorks for details about adding file formats at www.mathworks.com/products/mbc/.

Finding Items in the Calibration File

In a large calibration file, you might want to search for an item by name. To search the Contents of Calibration File pane:

  1. Click the Contents of Calibration File list.
  2. Type the first few letters of the item that you are searching for.
  3. The cursor moves to the letters specified as you type.

Copying Table Data from Other Sources

You can paste table values from Excel, for example, by copying the array in Excel and clicking Paste :

  1. Open the desired Excel file and copy the array that you want to import.
  2. In the Calibration Manager dialog box, click Paste .

You can also set up a table from a text file:

  1. Click  in the toolbar.
  2. Select the desired file, then click Open.


  Calibration Manager Table Properties