Instrument Control Toolbox | ![]() ![]() |
Send a trigger message to the instrument
Syntax
Arguments
obj |
A GPIB, VISA-GPIB, or VISA-VXI object. |
Description
trigger(obj)
sends a trigger message to the instrument connected to obj
.
Remarks
Before you can use trigger
, obj
must be connected to the instrument with the fopen
function. A connected instrument object has a Status
property value of open
. An error is returned if you attempt to use trigger
while obj
is not connected to the instrument.
For GPIB and VISA-GPIB objects, the Group Execute Trigger (GET) message is sent to the instrument.
For VISA-VXI objects, if the TriggerType
property is configured to software
, the Word Serial Trigger command is sent to the instrument. If TriggerType
is configured to hardware
, a hardware trigger is sent on the line specified by the TriggerLine
property.
Functions
Properties
Status
, TriggerLine
, TriggerType
![]() | tcpip | udp | ![]() |